Appendix A iX Pay™ Secure Payment Configuration U.S. Version
(Optional)
(SPM) EPP U.S. version 2.5.x.x.
For Canada see EMV documentation. For IEC see specific documents for the payment system
used.
Connection details of the iX Pay Secure Payment board and the SPM keypad are given in the
Helix Service Manual (WM048523). The board is installed on side A of the dispenser. A single
iX board controls both SPMs on a dual-sided dispenser with QVGA displays and softkeys.
The iX Pay Secure Payment board can be a red or green-colored board installed on side A of
the dispenser. A single iX Pay Secure Payment board controls both SPM’s on a dual-sided dis-
penser with QVGA displays.
Production dispensers with iX Pay Secure Payment are pre-configured at the factory. The con-
figuration at startup is to answer the screen prompts on side A. Once the CAT addresses (Ter-
minal IDs) are set from side A, and the correct side is confirmed, the information is copied to
side B. At the end of the configuration, the technician performs the diagnostic test on side A and
then puts side A into Operation. Once completed on side A, the technician needs to perform
only the Diagnostic test on side B and put side B into Operation.
To perform the configuration steps, at power-up, press the #2 softkey on the left side of the display
when the One Moment Please message is displayed. The screen sequence on initial Power
Up is given on the following pages.
Problems with the installation or startup of this product should be referred to DFS Support Center
at 1-800-926-3737.