6.24 Wayne Connect Module Replacement
Wayne Connect is optional equipment on Helix dispensers.
1
Turn off power at the dispenser switch.
2
Disconnect all cables from the module and release cables from the cable tie on the bracket.
3
Press and release the retaining tabs that secure the module bracket as shown in Fig 6.81.
There are two tabs on both sides of the bracket.
4
Remove the bracket.
5
Remove the two screws that secure the module to the bracket.
6
Install new module.
Note!
When reconnecting the cables to the two connectors at the bottom of the Wayne Connect module,
ensure that the cable coming from the Dispenser Connection board (J44-J45) connects to the
BB Bus (lower left) connector on the module and the cable coming from the iX board connects
to the LF Bus (lower right) connector on the module. If these cables are inadvertently swapped,
the payment terminal will be inoperative (offline).
tab
tab
2 tabs on this
side out of you
See NOTE
above for
connections
Figure 6.81: Wayne Connect Module
146 WM048523 Rev 08 01/2019
6 Replacement Procedures