15.3 Motor Replacement
1
Turn off power to dispenser.
2
Trip safety sheer valve.
3
Use 2.5 mm Allen wrench and remove three screws on pump side B and pull pump away
from motor. Fig 15.21.
Figure 15.21: Remove pump B
4
Repeat above step for the pump on side A. Fig 15.22.
Figure 15.22: Remove pump A
256 WM048523 Rev 08 01/2019
15 Helix 6000 DEF, Extra Narrow Model Dispensers - IEC