6.21 iX R2 Board Replacement
1
Turn off power at the dispenser switch.
2
Disconnect all wiring to the board. Fig 6.76.
3
Remove (6) Phillips screws and remove board.
4
Install new board.
Note!
The replacement iXR2 board must have the USB ports in the vertical position to allow access
to the ports.
5
Reconnect cables and turn on power.
6
Install the latest recommended software on the board.
7
Follow the iX R2 Startup Configuration procedures listed in the Appendix of this manual.
8
If site is using a Gateway, follow procedures for setting the IP address.
Figure 6.76: iXR2 Board
WM048523 Rev 08 01/2019 139