4
Remove screw that secures the side vent and remove vent as shown below.
Note: Production dispensers will have gasket material located under the vents and covers.
If for any reason the gaskets are moved during service, they should be reinstalled in their
original positions as shown below. Note that the outer gasket is weaved through the cables.
NOTICE!
Vapor Barrier Gaskets
The gasket on the ventilation panel should be
aligned with and press against the “weaved” gasket
to create a complete vapor barrier. All three gas-
kets (the one glued to the side panel, the weaved
gasket and the gasket glued to the ventilation
panel) should all be aligned to form a complete
vapor barrier when reassembled.
5
Repeat above step for opposite side vent.
238 WM048523 Rev 08 01/2019
14 Models with Metal Electronic Head - IEC