Troubleshooting
110 Operating Instructions 513/533 - 01.0 - 09/2023
E-058 Stepper motor
error loop DSP1
1
st
path (X27)
position error
The detected encoder response
position does not correspond to
the position specified in the
order.
Switch the stepper motor to
open loop mode and let it run.
If the motor is able to operate
normally, it is OK.
If the motor is unable to
operate normally, the user
should check the drive
component on the stepper
motor PCB and the motor itself.
After completing the
procedures above, the user
should check the encoder.
Make sure the connection
and the condition of the
encoder cable are OK.
Make sure the signal
response on the stepper
motor PCB and the encoder
itself are OK.
E-059 Stepper motor
error loop DSP1
1
st
path (X27)
overspeed
The system issues this warning
if detecting an abnormal speed
via the encoder response
signal.
The method used for
checking is the same as for
error E-058.
E-060 Stepper motor
error loop DSP1
1
st
path (X25)
overcurrent
The hardware has detected an
overcurrent.
Start by checking the motor
first.
Next, check the resistance
and the sensor reading.
If the motor is OK, check the
hardware on the stepper
motor card.
Error Description Possible cause Troubleshooting

Table of Contents

Related product manuals