Troubleshooting
110 Operating Instructions 513/533 - 01.0 - 09/2023
E-058 Stepper motor
error loop DSP1
1
st
path (X27)
position error
The detected encoder response
position does not correspond to
the position specified in the
order.
• Switch the stepper motor to
open loop mode and let it run.
• If the motor is able to operate
normally, it is OK.
• If the motor is unable to
operate normally, the user
should check the drive
component on the stepper
motor PCB and the motor itself.
• After completing the
procedures above, the user
should check the encoder.
• Make sure the connection
and the condition of the
encoder cable are OK.
• Make sure the signal
response on the stepper
motor PCB and the encoder
itself are OK.
E-059 Stepper motor
error loop DSP1
1
st
path (X27)
overspeed
The system issues this warning
if detecting an abnormal speed
via the encoder response
signal.
• The method used for
checking is the same as for
error E-058.
E-060 Stepper motor
error loop DSP1
1
st
path (X25)
overcurrent
The hardware has detected an
overcurrent.
• Start by checking the motor
first.
• Next, check the resistance
and the sensor reading.
• If the motor is OK, check the
hardware on the stepper
motor card.
Error Description Possible cause Troubleshooting