6. Appendices
6.1 Neutral Detect Active States
The following options are available to setup a Neutral Detect circuit.
*As soon as the throttle is returned to neutral, the wire fault will result in FC7 and Drive Inhibit.
Active
State
Switch in
Neutral
Switch
connected
to
Neutral
Driving
Short
circuit in
Neutral
Short circuit
while driving
Open
wire in
neutral
Open wire
while driving
Low
Closed
B- (Pin 13)
no
Fault
no
Fault
no
Fault
no Driving,
FC7
FC7
Cannot start
driving with
an open wire,
but a wire
break during
driving is not
detected*
High
Closed
B+ (Pin 7)
no
Fault
no
Fault
no
Fault
no Driving,
FC7
FC7
Cannot start
driving with
an open wire,
but a wire
break during
driving is not
detected*
Open
Open
B- (Pin 13)
or
B+ (Pin 7)
no
Fault
no
Fault
FC7
Cannot start
driving with a
short circuit,
but a short
circuit during
driving is not
detected*
no Fault
FC7

Table of Contents

Other manuals for Dynamic RHINO2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dynamic RHINO2 and is the answer not in the manual?

Dynamic RHINO2 Specifications

General IconGeneral
BrandDynamic
ModelRHINO2
CategoryController
LanguageEnglish

Related product manuals