4.4.7.7 Battery Gauge Sensitivity
Parameter
Possible Values
Default
HHP
Lite
Std
Adv
Battery Gauge Sensitivity
0 170
40
Adjusts the speed with which the battery gauge reacts to voltage fluctuations of the battery.
Batteries with a higher capacity take more time to discharge. For this reason, the battery
gauge should react slower with high-capacity batteries to ignore fast voltage fluctuations
that happen when the scooter encounters temporary loads such as a ramp.
If the battery voltage is less than the battery gauge currently indicates, the battery gauge
decreases by 5% after Battery Gauge Sensitivity x 1.5 seconds. The 100% range of the battery
gauge falls between Battery Gauge Minimum and Battery Gauge Maximum.
For better battery gauge accuracy, increase the value of Battery Gauge Sensitivity with high
capacity batteries and decrease the value with low-capacity batteries.