Chapter 3: Installation and Testing
47
3.11.1.2 Slows to
The Slows to parameter sets the speed to which the controller slows down when a Slow
function is active.
If set to 0%, the controller will decelerate at the programmed Emergency Deceleration rate
and apply the park brake.
If set to 100%, the Slow function will have no effect.
Any values between 0% and 100% will cause the controller to decelerate using the
programmed forward or reverse deceleration rate.
3.11.1.3 Latches
The Latches parameter sets whether the function will become latched once active. If a
function is latched, the active condition will have to be removed and the controller turned
off and then on again before the function will be turned off.
Note:
If 'Latches' is selected, please select 'Flashes' as well to indicate to the user why
the scooter will not drive.
3.11.1.4 Flashes
The Flashes parameter sets whether during a Drive Inhibit condition (when a Stop function is
active or a Charger Inhibit condition occurs) a flash code will be displayed. The flash code
that is displayed depends on the setting of the Flash Code Type parameter. See also
section 5.2: Flash Code Display.