Chapter 4: Programming the Rhino2
66
Beeper On Time and Beeper Off Time
together set the beeper interval time. During
Beeper On Time the beeper emits a sound.
During Beeper Off Time the beeper is silent.
4.4.1.10 Deep Discharge Beeper
Parameter
Possible Values
Default
HHP
Lite
Std
Adv
Deep Discharge Beeper
No / Yes
Yes
This parameter is only used when Enable Beeper has the value 'Yes'.
Enables beeping if the battery is drained to 90% of the cut-off level set by
Battery Cut-Off Voltage (4.4.7.5).
4.4.1.11 Sleep on Fault or Inhibit
Parameter
Possible Values
Default
HHP
Lite
Std
Adv
Sleep on Fault or Inhibit
No / Yes
Yes
Enables going to sleep if a fault or inhibit condition is active. If set to no, the unit will not go to
sleep, but will signal the fault indefinitely.
Notes:
If the value of Sleep Timer is zero, the value of Sleep on Fault or Inhibit
is ignored.
During a throttle fault or OONAPU fault the controller will never go to sleep,
even if this parameter is set to 'Yes'.
4.4.1.12 Power Off after Sleep
Parameter
Possible Values
Default
HHP
Lite
Std
Adv
Power Off after Sleep
No / Yes
Yes
Enables powering the unit off automatically after sleeping for approximately 6 hours to save
battery power.
Beeper Off Time
Time
Sound
Beeper On
Time

Table of Contents

Other manuals for Dynamic RHINO2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dynamic RHINO2 and is the answer not in the manual?

Dynamic RHINO2 Specifications

General IconGeneral
BrandDynamic
ModelRHINO2
CategoryController
LanguageEnglish

Related product manuals