4.4.3.2 Forward Acceleration
Parameter
Possible Values
Default
HHP
Lite
Std
Adv
Forward Acceleration
0 - 100 %
DS90:
35 % (Profile1)
35 % (Profile 2)
DS120:
30 % (Profile1)
30 % (Profile 2)
DS160:
20 % (Profile1)
20 % (Profile 2)

Sets how quickly the forward speed increases after the throttle has been deflected forward.
0 % - From standstill, the scooter reaches full forward speed in 10 s
100 % - From standstill, the scooter reaches full forward speed in 0.4 s
Low acceleration values give a softer performance and a less sensitive throttle response. High
acceleration values give a more aggressive performance and a fast throttle response.
Note:
This parameter cannot be set higher than the value of the Acceleration Limit
parameter (4.4.4.5) that has been set by the scooter manufacturer.
SPEED
TIME
Too high
Too sensitive
Jerky
Too low
Unresponsive
Long delays
Good
Smooth
Dependent on user
and environment