Chapter 4: Programming the Rhino2
73
4.4.2.12 Slam Brake
Parameter
Possible Values
Default
HHP
Lite
Std
Adv
Slam Brake Enable
No / Yes
No
Slam Brake Threshold
0 - 100 %
40 %

Slam Brake Enable turns on slam braking in the forward and reverse directions.
Slam Braking is applied when the throttle is significantly moved in the opposite direction to
the direction that the scooter is currently moving in (the minimum amount of throttle
movement in the opposite direction is set with Slam Brake Threshold)
During a slam brake, the scooter decelerates with the rate that is set with the Slam Braking
parameter (4.4.3.12). Be careful when enabling slam braking because this setting may not be
suitable for all scooter types.
4.4.2.13 Enable SRW Open Circuit Testing
Parameter
Possible Values
Default
HHP
Lite
Std
Adv
Enable SRW Open Circuit
Testing
No / Yes
No
When Enable SRW Open Circuit Testing is enabled, a fault will be generated when the SRW
resistor is disconnected. This is useful for detecting open circuit faults (e.g. broken wire) in the
SRW circuit.