2017.06.19 FwdMan2.8.17.docx
19-160
[13,18] 200 Distance from center Chnl.2
[19,24] -200 - - - - 3
etc. in fields: [25,30] [31,36] [37,42] [43,48] ...
4. "C:\DYNATEST\DATA\ .F200H20"
[1,2] C: Working Disc Drive
[3,28] \DYNA... Working Directory (26 characters max).
[29,32] .F20 FWD Data file Extension.
[33,33] 1 History Mode (NA)
[34,36] MDB History stored in database
5. "Generatorvej 21 ...
[1,60] Roadway Identification.
6. NA
7. NA
8. "SUR-035 AIR-123 0.000 5.150 5.050 0.100 0.000"
[1,8] SUR-035 Surface temperature sensor SN
[9,16] AIR-123 Air temperature sensor SN
[17,24] 1000 Lowest Station
[25,32] 1150 Highest Station
[33,40] 1150 Previous Station
[41,48] 100 Station Step
[49,56] 0.000 NA
9. " 2015.0 3.5 5.0 2.015.0 2.0 5.0"
Limits, four characters each.
[1,4] 20 Vibr/Drift Limit (mu or mil)
[5,8] 15.0 Lower Plate Time Limit
[9,12] 3.5 Raise.Weight - (1.Stop)
[13,16] 5.0 Lower Catch - (NO Pres2)
[17,20] 2.0 Drop - (till TG)
[21,24] 15.0 Raise Plate -
[25,28] 2.0 Raise Weight - (til NO TG)
[29,32] 5.0 Raise Catch -
10. "Ld XXX 1.000 89.00 ."
[1,3] Ld Load Cell Id.
[4,11] XXX Serial No
[12] Space
[13,17] 1.000 Relative Gain
[18] Space
[19,23] 89.00 Absolute Gain
[24,32] Reserved.
11. to 20. Deflector Serial Numbers and Gains similar to line 10.
A vacant Deflector channel looks like:
"D9 NA 0.000 0.000 ."
21. "Operator Name ....
[1,32] Operator Name.
22. Test Units and Options.
"00 20100002 1 1 ."
[1] 0 Deflections 0=mu 1=mil
[2] 0 Temperatures 0=C 1=F
[3] NA
[4] NA
[5] NA
[6] 2 Location 2=Meters
3=km
5=feet

Table of Contents