2017.06.19 FwdMan2.8.17.docx 19-165
[33,38] Radius of plate (inches)
[39,44] Zero
[45,50] Distance from center Chnl.2 (inches)
[51,56] - - - - 3 -
[57,62] - - - - 4 -
[63,68] - - - - 5 -
[69,74] - - - - 6 -
[75,80] - - - - 7 -
4. "C:\DYNATEST\DATA\ .FWD"
[1,2] C: Working Disc Drive
[3,28] \DYNA... Working Directory (26 characters max).
[29,32] .FWD FWD/HWD Data file Extension.
5. "Generatorvej 21 ...
[1,32] or [1,60] Roadway Identification.
6. "S 11506hvv 20.000 20 20020930"
Copy of last STATION ID stored in file (see line 38).
7. "S 12006hvv 20.000 20 20020930"
Next Expected STATION ID.
8. "SUR-MAN AIR-MAN 1000 1150"
[1,8] SUR-MAN Surface “Xducer”
[9,16] AIR-MAN Air “Xducer”
[17,24] 1000 Lowest “Station”
[25,32] 1150 Highest “Station”
9. " 2015.0 3.5 5.0 2.015.0 2.0 5.0"
Limits, four characters each.
[1,4] 20 Vibr/Drift Limit (mu or mil)
[5,8] 15.0 Lower Plate Time Limit
[9,12] 3.5 Raise.Weight - (1.Stop)
[13,16] 5.0 Lower Catch - (NO Pres2)
[17,20] 2.0 Drop - (till TG)
[21,24] 15.0 Raise Plate -
[25,28] 2.0 Raise Weight - (til NO TG)
[29,32] 5.0 Raise Catch -
10. "LdXXX 1.000 89.00 ."
[1,2] Ld Load Cell Id.
[3,10] XXX Serial No (File Name)
[11,15] 1.000 Relative Gain
[16,18] Reserved
[19,23] 89.00 Absolute Gain
[24,32] Reserved.
11. to 20. Deflector Serial Numbers and Gains similar to line 10.
A vacant Deflector channel looks like:
"D0NA 0.0000.000 ."
21. "Operator Name ....
[1,32] Operator Name.
22. "0000120100002 1 1 ."
Test Units and Options.
[1] 0 Deflections 0=mu 1=mil
[2] 0 Temperatures 0=“C 1=“F
[3] 0 Stn. Prompt 0=OFF 1=ON
[4] 0 Decrease Check 0=OFF 1=ON
[5] 1 Rejection 0=OFF 1=ON
[6] 2 Location 2=Meters
3=km