186
Appendix A—Parameter ID list
POWERXL SERIES VFD MN040010EN—June 2018 www.eaton.com
Menu
Item
No.
Modbus
Register
PROFIBUS EtherNet/IP DeviceNet
Parameter
Description
Data
Type
Length
(in Bytes)
Display
FormatPNU
PNU
SubIndex Class Instance Attribute Class Instance Attribute
P8.40_ 1623 105 0 163 1 235 168 1 67 Flux Current Ramp
Time
INTEGER 2 x0
P8.41_ 1624 118 2 163 1 236 168 1 68 Zero Speed Start
Time
INTEGER 2 x0
P8.42_ 1625 118 3 163 1 237 168 1 69 Zero Speed Stop
Time
INTEGER 2 x0
P8.43 1630 2902 0 163 1 241 168 1 70 Droop Control Filter
Time Constant
INTEGER 2 x0
P8.44 1631 420 4 163 1 242 168 1 71 Startup Torque
Selection
INTEGER 2 x0
P8.45 1632 2 3 163 1 243 168 1 72 Torque Memory Start INTEGER 2 x10
P8.46 1633 36 0 163 1 244 168 1 73 Startup Torque
Forward
INTEGER 2 x10
P8.47 1634 37 0 163 1 245 168 1 74 Startup Torque
Reverse
INTEGER 2 x10
P8.48 1635 506 1 163 1 246 168 1 75 Startup Torque Actual INTEGER 2 x10
P8.49 1667 133 0 164 1 21 168 1 76 Startup Torque Time INTEGER 2 x0
P8.50 771 218 0 162 1 123 168 1 77 Stator Resistor INTEGER 2 x1000
P8.51_ 772 221 0 162 1 124 168 1 78 Rotor Resistor INTEGER 2 x1000
P8.52 773 224 0 162 1 125 168 1 79 Leak Inductance INTEGER 2 x100
P8.53_ 774 225 0 162 1 126 168 1 80 Mutual Inductance INTEGER 2 x10
P8.54 775 223 0 162 1 127 168 1 81 Excitation Current INTEGER 2 x10
P8.55_ 58 NA NA NA NA NA NA NA NA Advanced Open Loop
Options
DOUBLE 4 x0
P8.56_ 63 NA NA NA NA NA NA NA NA Torque Stability Gain INTEGER 2 x10
P8.57_ 64 NA NA NA NA NA NA NA NA Torque Stability FWP
Gain
INTEGER 2 x10
P8.58_ 62 NA NA NA NA NA NA NA NA Torque Stability
Dampening Time
INTEGER 2 x10000
P9.1306840295201601182169114mA Input FaultBYTE1x0
P9.233117 1601183169124mA Fault FrequencyINTEGER2x100
P9.330784036864160119716913External FaultBYTE1x0
P9.433284012592160119816914Input Phase FaultBYTE1x0
P9.533084012576160120216915Uvolt Fault ResponseBYTE1x0
P9.6 308 840 9040 160 1 199 169 1 6 Output Phase Fault BYTE 1 x0
P9.73098409008160120316917Ground Fault BYTE1x0
P9.831084017168160119216918Motor Thermal
Protection
BYTE 1 x0
P9.9 311 1012 0 160 1 193 169 1 9 Motor Thermal F0
Current
INTEGER 2 x10
P9.10 312 1011 0 160 1 194 169 1 10 Motor Thermal Time BYTE 1 x0
P9.11 313 840 28963 160 1 184 169 1 11 Stall Protection BYTE 1 x0
P9.12 314 1010 0 160 1 185 169 1 12 Stall Current Limit INTEGER 2 x10
P9.13 315 1010 1 160 1 186 169 1 13 Stall Time Limit INTEGER 2 x10
P9.14 316 1010 2 160 1 187 169 1 14 Stall Frequency Limit INTEGER 2 x100
P9.15317840289791601188169115Underload ProtectionBYTE1x0
P9.16 318 1013 0 160 1 189 169 1 16 Underload Fnom
Torque
INTEGER 2 x10
P9.17 319 1013 1 160 1 190 169 1 17 Underload F0 Torque INTEGER 2 x10
P9.1832010111 1601191169118Underload Time LimitINTEGER2x100
P9.19 333 840 28978 160 1 201 169 1 19 Thermistor Fault
Response
BYTE 1 x0
P9.20 750 861 0 162 1 83 169 1 20 Line Start Lockout BYTE 1 x0
Table 205. DG1 Parameter ID list, continued