(20) Fixed green LED: hoist is active.
Flashing green LED: hoist is active
with automatic rope movement
enabled (AWC).
(23) Fixed yellow: warning due to three
possible causes:
- max. geometric configuration
reached.
- close to the max. crane
performance limit.
- stabiliser not set on to the
ground.
For further information about the
warnings present, go to the menu
(F3).
(21) Fixed yellow LED: HSS is active.
(22) Blinking green: automatic max.
speed reduction during the
operation.
(24) Fixed red: alarms.
For further information about the
alarms present, go to the menu
(F3).
(a) Battery status (f) Lights enabled [option]
(b) Limit load percentage (g)
(g1)
MEWP mode [option]
Rotator/grapple mode [option]
(c) Weight detected [option]
(d) Radio hook battery status [option] (h)
(h1)
Cabin protection enabled [option]
Operator protection enabled
[option]
(e)
(e1)
Partial bypass enabled
Progress bypass enabled
F1: Settings Set the hoist pulls on the tip of the crane (n. of winch shots/lines) or set the
radio hook according to the hook installed.
The control system
EFFER 265-315-395-525 Progress 2.0 CE 59