IP Server 1... 3 – encryption key 0000
Communication - primary IP Server 1 (GPRS)
Communication – backup 1... 5 N/A
Retry after delay N/A
Delay after last communication attempt 1200 seconds
SIA IP protocol settings - encryption Disabled
SIA IP protocol settings – encryption key 0000
SIA IP protocol settings – account prex N/A
SIA IP protocol settings – receiver number N/A
SIA IP protocol settings – use time stamp Enabled
SIA IP protocol settings – Contact ID ping Disabled
SIA IP protocol settings – data message Event: 1602, partition: 01, user/zone: 000
Data Messages
Burglary alarm/restore – code 130
Burglary alarm/restore – status Enabled
Main power loss/restore – code 301
Main power loss/restore – status Enabled
Armed/disarmed by user – code 401
Armed/disarmed by user – status Enabled
Test event – code 602
Test event – status Enabled
Battery failed – code 309
Battery failed – status Enabled
Battery dead or missing – code 311
Battery dead or missing – status Enabled
Tamper alarm/restore – code 144
Tamper alarm/restore – status Enabled
Instant Silent zone alarm/restore – code 146
Instant Silent zone alarm/restore – status Enabled
Kronos ping – code 602
Kronos ping – status Enabled
System started – code 900
System started – status Enabled
24H zone alarm/restore – code 133
24H zone alarm/restore – status Enabled
Fire zone alarm/restore – code 110
Fire zone alarm/restore – status Enabled
Low battery – code 302
Low battery – status Enabled
Temperature exceeded – code 158
Temperature exceeded – status Enabled
Temperature fallen – code 159
Temperature fallen – status Enabled
Wireless signal loss/restore – code 381
Wireless signal loss/restore – status Enabled
Disarmed by user (duress code) – code 121
Disarmed by user (duress code) – status Enabled
SGS code entered – code 463
SGS code entered – status Enabled
Armed by user (partial arm) – code 456
Armed by user (partial arm) – status Enabled
RF jammer detected - code 344
RF jammer detected - status Enabled
Siren fail/restore – code 321
Siren fail/restore – status Disabled
Date/time not set – code 626
Date/time not set – status Enabled
GSM connection failed – code 358
GSM connection failed – status Enabled
GSM/GPRS antenna fail/restore – code 359
GSM/GPRS antenna fail/restore – status Disabled
System shutdown – code 414
System shutdown – status Enabled
Communication bus fail/restore – code 330