EasyManua.ls Logo

Eldes ESIM384 - Page 151

Eldes ESIM384
198 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
151
151
EN
ESIM384 Installation and Conguration Manual v1.1
Set attempts
EKB2
Menu path:
Server 1: OK → iiii → OK → MS SETTINGS → OK → IP SETTINGS → OK → SERVER IP → OK → IP
ATTEMPTS → OK → att → OK
Server 2: ... → SERVER2 IP → OK → IP ATTEMPTS → OK → att → OK
Server 3: ... → SERVER3 IP → OK → IP ATTEMPTS → OK → att → OK
Value: iiii – 4-digit installer code; att – number of attempts, range – [1... 255].
EKB3/
EKB3W/
EWKB4
Enter parameter 68 and number of attempts/parameter 96, parameter number
and number of attempts:
Server 1: 68 att #
Server 2: 96 08 att #
Server 3: 96 09 att #
Value: att – number of attempts, range – [01... 255].
Example: 6809#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
To report the online status, the system periodically transmits (by default – every 180 seconds) Test Event data message (ping) to the mon-
itoring station via GPRS network or Ethernet.
Set test period
EKB2
Menu path:
Server 1: OK → iiii → OK → MS SETTINGS → OK → IP SETTINGS → OK → SERVER IP → OK → TEST
PERIOD → OK → tteessttpp → OK
Server 2: ... → SERVER2 IP → OK → TEST PERIOD → OK → tteessttpp → OK
Server 3: ... → SERVER3 IP → OK → TEST PERIOD → OK → tteessttpp → OK
Value: iiii – 4-digit installer code; tteessttpp – test period, range – [0... 65535] seconds.
EKB3/
EKB3W/
EWKB4
Enter parameter 46 and number of attempts/parameter 96, parameter number
and number of attempts:
Server 1: 46 tteessttpp #
Server 2: 96 10 tteessttpp #
Server 3: 96 11 tteessttpp #
Value: tteessttpp – test period, range – [0... 65535] seconds.
Example: 46120#
ELDES
Cong-
uration
soft-
ware
This operation may be carried out from the PC using the ELDES Conguration software.
NOTE: 0 value disables test period. However, disabling the test period is HIGHLY UNRECOMMENDED.
Unit ID is a 4-digit number (By default – 0000) required to identify the alarm system unit by EGR100 middle-ware. It is RECOMMENDED to
change the default Unit ID before using EGR100.
Set unit ID
EKB2
Menu path:
Server 1: OK → iiii → OK → MS SETTINGS → OK → IP SETTINGS → OK → SERVER IP → OK → UNIT
ID → OK → unid → OK
Server 2: ... → SERVER2 IP → OK → UNIT ID → OK → unid → OK
Server 3: ... → SERVER3 IP → OK → UNIT ID → OK → unid → OK
Value: iiii – 4-digit installer code; unid – 4-digit unit ID number.
EKB3/
EKB3W/
EWKB4
Enter parameter 47 and unit ID number/parameter 96, parameter number and unit
ID number:
Server 1: 47 unid #
Server 2: 96 14 unid #
Server 3: 96 15 unid #
Value: unid – 4-digit unit ID number.
Example: 472245#

Table of Contents