EasyManua.ls Logo

Eldes ESIM384 - Page 150

Eldes ESIM384
198 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
150
150
EN
ESIM384 Installation and Conguration Manual v1.1
EKB3/
EKB3W/
EWKB4
Enter parameter 42 and DNS2 server IP address:
42 add add add add #
Value: add add add add – DNS2 server IP address
.
Example: 42065082119002#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
Set protocol
SMS
SMS text message content:
Server 1: ssss_SETGPRS:PROTOCOL:ptc
Value: ssss – 4-digit SMS password; ptc – protocol, range – [TCP... UDP].
Example: 1111_SETGPRS:PROTOCOL:UDP
EKB2
Menu path:
Server 1: OK iiii OK MS SETTINGS OK IP SETTINGS OK SERVER IP OK
PROTOCOL OK TCP | UDP OK
Server 2: ... SERVER2 IP OK PROTOCOL OK TCP | UDP OK
Server 3: ... SERVER3 IP OK PROTOCOL OK TCP | UDP OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 43 and protocol number/parameter 96, parameter number and
protocol number:
Server 1: 43 0 # - TCP | 43 1 # - UDP
Server 2: 96 06 0 # - TCP | 96 06 1 # - UDP
Server 3: 96 07 0 # - TCP | 96 07 1 # - UDP
Example: 431#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
Set data format as
Kronos, EGR100 or
SIA IP
ELDES
Cong-
uration
soft-
ware
This operation may be carried out from the PC using the ELDES Conguration software.
Manage SIA IP data
format parameters
ELDES
Cong-
uration
soft-
ware
This operation may be carried out from the PC using the ELDES Conguration software.
Set encryption key
for EGR100 data
format
ELDES
Cong-
uration
soft-
ware
This operation may be carried out from the PC using the ELDES Conguration software.
ATTENTION: It is necessary to restart the system locally by powering down and powering up the system the system or remotely (see 34.
REMOTE SYSTEM RESTART) after changing the IP address or switching from TCP to UDP.
NOTE: Kronos NET/Kronos LT software communicates via TCP protocol, while EGR100 middle-ware v1.2 and up supports both – TCP and
UDP protocols.
By default, if the initial attempt to transmit data to the monitoring station via GPRS network or Ethernet method is unsuccessful, the sys-
tem will make up to 3 additional attempts. If all attempts are unsuccessful, the system will switch to next backup connection that follows in
the sequence and will attempt to transmit data until it is successfully delivered to the monitoring station.