154
154
EN
ESIM384 Installation and Conguration Manual v1.1
Delete monitoring
station phone number
EKB2
Menu path:
OK iiii OK MS SETTINGS OK VOICE CALLS/SMS ST OK TEL. NUMBER 1... 3
OK OK
Value: iiii – 4-digit installer code.
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
By default, if the initial attempt to transmit data to the monitoring station’s Tel Number 1 via Voice Calls or SMS method is unsuccessful,
the system will make up to 2 additional attempts. After all unsuccessful attempts, the system will continue to communicate with the mon-
itoring station by switching to the next phone number that follows in the sequence and making up to 2 additional attempts if the initial
attempt was unsuccessful. If all attempts to all phone numbers are unsuccessful, the system will switch to next backup connection that
follows in the sequence and will attempt to transmit data until it is successfully delivered to the monitoring station.
Set attempts
EKB2
Menu path:
OK iiii OK MS SETTINGS OK VOICE CALLS/SMS ST OK ATTEMPTS OK
at OK
Value: iiii – 4-digit installer code; at – number of attempts, range – [1... 10].
EKB3/
EKB3W/
EWKB4
Enter parameter 37 and number of attempts:
37 at #
Value: at – number of attempts, range – [01... 10].
Example: 3706#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
Due to the individual conguration of each monitoring station, the system may fail to deliver the data message via Voice Calls communi-
cation method. In such cases it is recommended to adjust the microphone gain and speaker level until the optimal value is discovered (de-
pending on which error appears: synchro error - speaker level; no kisso - microphone gain), leading to successful data message delivery.
Set microphone gain
EKB2
Menu path:
OK iiii OK PRIMARY SETT INGS OK GSM AUDIO OK MICROPHONE GAIN OK
mg OK
Value: iiii – 4-digit installer code; mg – microphone gain, range – [0... 15].
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
ATTENTION: When using the SMS data transmission method, the system will notify the monitoring station and the user once the SMS de-
livery limit is exceeded. In such case, the system will no longer be able to send out any SMS text messages neither to the monitoring station
nor to the user, unless the SMS text message delivery limit is reset by the user or automatically. For more details, please refer to 27.1. SMS
Text Message Delivery Restrictions.