EasyManua.ls Logo

Eldes ESIM384 - Page 19

Eldes ESIM384
198 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
19
EN
ESIM384 Installation and Conguration Manual v1.1
NOTE: The system does NOT support 2-wire smoke detectors.
Type 3 Example of motion detector wiring
Z1
COM
COM
AUX+
AUX-
+Vin
GND
NC
TAMP
5,6 kΩ 3,3 kΩ
Z COM
NO
EOL 5.6K
Z COM
NC
EOL 5.6K
Z COM
NC
NC
5.6K
3.3K
Z COM
NC
3.3K
EOL 5.6K
TAMPER
Z COM
NC
3.3K
NC
5.6K
EOL 5.6K
TAMPER
5
8-Zone mode: Tamper
and 5,6K end-of-line
resistor and 3,3K
end-of-line resistor
with normally closed
contact.
Type 4 Example of magnetic door contact (Z1) and glass break sensor (Z9) wiring
AUX+
+Vin
AUX-
GND
COM
COM
NC
NC
COM
Z1
5,6 kΩ
3,3 kΩ
Magnet
Z COM
NO
EOL 5.6K
Z COM
NC
EOL 5.6K
Z COM
NC
NC
5.6K
3.3K
Z COM
NC
3.3K
EOL 5.6K
TAMPER
Z COM
NC
3.3K
NC
5.6K
EOL 5.6K
TAMPER
6
ATZ mode: 5,6K
end-of-line resistor
and normally closed
contact with 3,3K
end-of-line resistor
and normally closed
contact
Type 5 Example of motion detector (Z1) and magnetic door contact (Z9) wiring
Z COM
NO
EOL 5.6K
Z COM
NC
EOL 5.6K
Z COM
NC
NC
5.6K
3.3K
Z COM
NC
3.3K
EOL 5.6K
TAMPER
Z COM
NC
3.3K
NC
5.6K
EOL 5.6K
TAMPER
Z1
COM
COM
COM
AUX+
AUX-
+Vin
GND
NC
NC
TAMP
5,6 kΩ5,6 kΩ 3,3 kΩ
Magnet
ATZ mode: Tamper,
5,6K end-of-line
resistor, 5,6K
end-of-line resistor
with normally closed
contact and 3,3K
end-of-line resistor
with normally closed
contact.
7
See also 14.3. 8-Zone Mode and 14.4. ATZ (Advanced Technology Zone) Mode.

Table of Contents

Related product manuals