ProlineйPromagйHй100йEtherNet/IP Electricalйconnection
Endress+Hauser 33
7.3 Special connection instructions
7.3.1 Connection examples
EtherNet/IP
ййA0016805
11 Connection example for EtherNet/IP
1 Control system (e.g. PLC)
2 Ethernet switch
3 Observe cable specifications (→ 27)
4 Connector
5 Transmitter
7.4 Hardware settings
7.4.1 Setting the device address
EtherNet/IP
TheйIPйaddressйofйtheйmeasuringйdeviceйcanйbeйconfiguredйforйtheйnetworkйviaйDIPйswitches.
Addressing data
IP address and configuration options
1stйoctet 2ndйoctet 3rdйoctet 4thйoctet
192. 168. 1. XXX
Canйonlyйbeйconfiguredйviaйsoftwareйaddressing Canйbeйconfiguredйvia
softwareйaddressing
andйhardware
addressing
IP address range 1йtoй254йс4thйoctet)
IP address broadcast 255
Addressing mode ex
works
Softwareйaddressing;йallйDIPйswitchesйforйhardwareйaddressingйareйsetйtoйOFF.
IP address ex works DHCPйserverйactive
Forйdeviceйaddressingйviaйsoftwareйсййй48)