Parameter Description User interface / Selection /
User entry
Factory setting
Subnetйmask Displaysйtheйsubnetйmask. 4йoctet:й0йtoй255йсinйthe
particularйoctet)
255.255.255.0
Defaultйgateway Displaysйtheйdefaultйgateway. 4йoctet:й0йtoй255йсinйthe
particularйoctet)
0.0.0.0
10.3.5 Configuring the low flow cut off
TheйLow flow cut offйsubmenuйcontainsйparametersйthatйmustйbeйconfiguredйforйthe
configurationйofйlowйflowйcutйoff.
Navigation
"Setup"йmenuййLowйflowйcutйoff
Structure of the submenu
Low flow cut off
Assignйprocessйvariable
Onйvalueйlowйflowйcutoff
Offйvalueйlowйflowйcutoff
Pressureйshockйsuppression
Parameter overview with brief description
Parameter Prerequsite Description Selection / User
entry
Factory setting
Assignйprocessйvariable – Selectйprocessйvariableйforйlow
flowйcutйoff.
• Off
• Volumeйflow
• Massйflow
• Correctedйvolume
flow
Volumeйflow
Onйvalueйlowйflowйcutoff Oneйofйtheйfollowingйoptionsйis
selectedйinйtheйAssign process
variableйparameter:
• Massйflow
• Volumeйflow
• Correctedйvolumeйflow
Enterйonйvalueйforйlowйflowйcut
off.
Signedйfloating-point
number
Forйliquids:йdepends
onйcountryйand
nominalйdiameter
Offйvalueйlowйflowйcutoff Oneйofйtheйfollowingйoptionsйis
selectedйinйtheйAssign process
variableйparameter:
• Massйflow
• Volumeйflow
• Correctedйvolumeйflow
Enterйoffйvalueйforйlowйflowйcut
off.
0йtoй100.0й% 50й%
Pressureйshockйsuppression Oneйofйtheйfollowingйoptionsйis
selectedйinйtheйAssign process
variableйparameter:
• Massйflow
• Volumeйflow
• Correctedйvolumeйflow
Enterйtimeйframeйforйsignal
suppressionйс=йactiveйpressure
shockйsuppression).
0йtoй100йs 0йs