ProlineйPromagйHй100йEtherNet/IP Commissioning
Endress+Hauser 61
Parameter Prerequsite Description Selection / User
entry
Factory setting
Simulationйdeviceйalarm Switchйtheйdeviceйalarmйonйand
off.
Off
On
Off
Simulationйdiagnosticйevent Switchйsimulationйofйthe
diagnosticйeventйonйandйoff.
Forйtheйsimulation,йyouйcan
chooseйfromйtheйdiagnostic
eventsйofйtheйcategoryйselected
inйtheйDiagnostic event
categoryйparameter.
Off
Picklist
Diagnosticйevents
сdependsйonйthe
selectedйcategory)
Off
10.6 Protecting settings from unauthorized access
Theйfollowingйoptionsйexistйforйprotectingйtheйconfigurationйofйtheйmeasuringйdeviceйfrom
unintentionalйmodificationйafterйcommissioning:
WriteйprotectionйviaйaccessйcodeйforйWebйbrowserйсййй61)
Writeйprotectionйviaйwriteйprotectionйswitchйсййй61)
10.6.1 Write protection via access code
Withйtheйcustomer-specificйaccessйcode,йaccessйtoйtheйmeasuringйdeviceйviaйtheйWeb
browserйisйprotected,йasйareйtheйparametersйforйtheйmeasuringйdeviceйconfiguration.
Navigation
"Setup"йmenuййAdvancedйsetupййAdministrationййDefineйaccessйcode
Structure of the submenu
Define access code
Defineйaccessйcode
Confirmйaccessйcode
Defining the access code via the Web browser
1. NavigateйtoйtheйEnter access codeйparameter.
2. Defineйaйmax.й4-digitйnumericйcodeйasйanйaccessйcode.
3. Enterйtheйaccessйcodeйagainйtoйconfirmйtheйcode.
TheйWebйbrowserйswitchesйtoйtheйloginйpage.
Ifйnoйactionйisйperformedйforй10йminutes,йtheйWebйbrowserйautomaticallyйreturnsйto
theйloginйpage.
TheйuserйroleйwithйwhichйtheйuserйisйcurrentlyйloggedйonйviaйtheйWebйbrowserйis
indicatedйbyйtheйAccess status toolingйparameter.йNavigationйpath:йOperationй
Accessйstatusйtooling
10.6.2 Write protection via write protection switch
Theйwriteйprotectionйswitchйmakesйitйpossibleйtoйblockйwriteйaccessйtoйtheйentireйoperating
menuйwithйtheйexceptionйofйtheйfollowingйparameters:
Externalйpressure
Externalйtemperature
Referenceйdensity
Allйparametersйforйconfiguringйtheйtotalizer

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Proline Promag H 100 EtherNet/IP and is the answer not in the manual?

Endress+Hauser Proline Promag H 100 EtherNet/IP Specifications

General IconGeneral
BrandEndress+Hauser
ModelProline Promag H 100 EtherNet/IP
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals