ProlineйPromagйHй100йEtherNet/IP Commissioning
Endress+Hauser 61
Parameter Prerequsite Description Selection / User
entry
Factory setting
Simulationйdeviceйalarm – Switchйtheйdeviceйalarmйonйand
off.
• Off
• On
Off
Simulationйdiagnosticйevent – Switchйsimulationйofйthe
diagnosticйeventйonйandйoff.
Forйtheйsimulation,йyouйcan
chooseйfromйtheйdiagnostic
eventsйofйtheйcategoryйselected
inйtheйDiagnostic event
categoryйparameter.
• Off
• Picklist
Diagnosticйevents
сdependsйonйthe
selectedйcategory)
Off
10.6 Protecting settings from unauthorized access
Theйfollowingйoptionsйexistйforйprotectingйtheйconfigurationйofйtheйmeasuringйdeviceйfrom
unintentionalйmodificationйafterйcommissioning:
• WriteйprotectionйviaйaccessйcodeйforйWebйbrowserйсййй61)
• Writeйprotectionйviaйwriteйprotectionйswitchйсййй61)
10.6.1 Write protection via access code
Withйtheйcustomer-specificйaccessйcode,йaccessйtoйtheйmeasuringйdeviceйviaйtheйWeb
browserйisйprotected,йasйareйtheйparametersйforйtheйmeasuringйdeviceйconfiguration.
Navigation
"Setup"йmenuййAdvancedйsetupййAdministrationййDefineйaccessйcode
Structure of the submenu
Define access code
Defineйaccessйcode
Confirmйaccessйcode
Defining the access code via the Web browser
1. NavigateйtoйtheйEnter access codeйparameter.
2. Defineйaйmax.й4-digitйnumericйcodeйasйanйaccessйcode.
3. Enterйtheйaccessйcodeйagainйtoйconfirmйtheйcode.
TheйWebйbrowserйswitchesйtoйtheйloginйpage.
Ifйnoйactionйisйperformedйforй10йminutes,йtheйWebйbrowserйautomaticallyйreturnsйto
theйloginйpage.
TheйuserйroleйwithйwhichйtheйuserйisйcurrentlyйloggedйonйviaйtheйWebйbrowserйis
indicatedйbyйtheйAccess status toolingйparameter.йNavigationйpath:йOperationй
Accessйstatusйtooling
10.6.2 Write protection via write protection switch
Theйwriteйprotectionйswitchйmakesйitйpossibleйtoйblockйwriteйaccessйtoйtheйentireйoperating
menuйwithйtheйexceptionйofйtheйfollowingйparameters:
• Externalйpressure
• Externalйtemperature
• Referenceйdensity
• Allйparametersйforйconfiguringйtheйtotalizer