Technicalйdata ProlineйPromagйHй100йEtherNet/IP
94 Endress+Hauser
Pressureйlossй • NoйpressureйlossйoccursйasйofйnominalйdiameterйDNй8йс3/8")йifйtheйsensorйisйinstalledйinйa
pipeйwithйtheйsameйnominalйdiameter.
• PressureйlossesйforйconfigurationsйincorporatingйadaptersйaccordingйtoйDINйENй545
сййй21)
Systemйpressure сййй20)
Vibrations сййй20)
16.10 Mechanical construction
Design,йdimensions
Forйtheйdimensionsйandйinstallationйlengthsйofйtheйdevice,йseeйtheй"Technical
Information"йdocument,й"Mechanicalйconstruction"йsection
Weight Compact version
• Includingйtheйtransmitter
• Weightйspecificationsйapplyйtoйstandardйpressureйratingsйandйwithoutйpackaging
material.
Nominal diameter Weight
[mm] [in] [kg] [lbs]
2 1/12 2.00 4.41
4 1/8 2.00 4.41
8 3/8 2.00 4.41
15 ½ 1.90 4.19
25 1 2.80 6.17
40 1й½ 4.10 9.04
50 2 4.60 10.1
65 – 5.40 11.9
80 3 6.00 13.2
100 4 7.30 16.1
125 5 12.7 28.0
150 6 15.1 33.3
Measuringйtube
specification
Nominal diameter Pressure rating
1)
Process connection internal diameter
EN (DIN) PFA
[mm] [in] [bar] [mm] [in]
2 1/12 PNй16/40 2.25 0.09
4 1/8 PNй16/40 4.5 0.18
8 3/8 PNй16/40 9.0 0.35
15 ½ PNй16/40 16.0 0.63
– 1 PNй16/40 22.6 0.89
25 – PNй16/40 26.0 1.02
40 1й½ PNй16/25/40 35.3 1.39