4 Block QUICK SETUP Device Functions Proline Promass 83 MODBUS RS485
26 Endress+Hauser
Settings for the Batching Setup menu:
Fct. code Function name Suggested settings Description
Call up through the function matrix:
B QUICK SETUP QUICK SETUP BATCHING/DOSING see P. 20
1005 QUICK SETUP
BATCHING/DOSING
YES see P. 20
Settings (functions with a gray background are set automatically):
6400 ASSIGN LOW FLOW CUT OFF Mass see P. 109
6402 ON-VALUE
LOW FLOW CUTOFF
Depends on diameter (DN [mm]):
– DN 1 = 0.02 [kg/h] resp. [l/h]
– DN 2 = 0.10 [kg/h] resp. [l/h]
– DN 4 = 0.45 [kg/h] resp. [l/h]
– DN 8 = 2.0 [kg/h] resp. [l/h]
– DN 15 = 6.5 [kg/h] resp. [l/h]
– DN 15* = 18 [kg/h] resp. [l/h]
– DN 25 = 18 [kg/h] resp. [l/h]
– DN 25* = 45 [kg/h] resp. [l/h]
– DN 40 = 45 [kg/h] resp. [l/h]
– DN 40* = 70 [kg/h] resp. [l/h]
– DN 50 = 70 [kg/h] resp. [l/h]
– DN 50* = 180 [kg/h] resp. [l/h]
– DN 80 = 180 [kg/h] resp. [l/h]
– DN 100 = 350 [kg/h] resp. [l/h]
– DN 150 = 650 [kg/h] resp. [l/h]
– DN 250 = 1800 [kg/h] resp. [l/h]
*DN 15, 25, 40, 50 “FB” = Full bore
versions of Promass I
see P. 109
6403 OFF-VALUE LOW FLOW CUT OFF 50% see P. 109
6603 FLOW DAMPING 0 seconds see P. 118
6404 PRESSURE SHOCK SUPPRESSION 0 seconds see P. 110
7200 BATCH SELECTOR BATCH #1 see P. 131
7201 BATCH NAME BATCH #1 see P. 132
7202 ASSIGN BATCH VARIABLE Mass flow see P. 131
7203 BATCH QUANTITY 0 see P. 132
7204 FIX COMPENSATION QUANTITY 0 see P. 133
7205 COMPENSATION MODE OFF see P. 133
7208 BATCH STAGES 1 see P. 136
7209 INPUT FORMAT Value input see P. 137
4700 ASSIGN RELAY BATCHING VALVE 1 see P. 93
4780 TERMINAL NUMBER Output (display only) see P. 98
7220 OPEN VALVE 1 0% or 0 [unit] see P. 138
7240 MAXIMUM BATCHING TIME 0 seconds (Off) see P. 143
7241 MINIMUM BATCHING
QUANTITY
0 seconds see P. 143
7242 MAXIMUM BATCHING
QUANTITY
0 seconds see P. 144
2200 ASSIGN (Main line) BATCH NAME see P. 37
2220 ASSIGN (
Multiplex main line)
Off see P. 39
2400 ASSIGN (Additional line) BATCH DOWNWARDS see P. 41
2420 ASSIGN (
Multiplex additional line)
Off see P. 44
2600 ASSIGN (Info line) BATCHING KEYS see P. 47
2620 ASSIGN (Multiplex info line) Off see P. 50