EasyManuals Logo

Epson RC700 Series User Manual

Epson RC700 Series
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #139 background imageLoading...
Page #139 background image
Maintenance 4. Backup and Restore
RC700 / RC700-A Rev.23 127
4. Backup and Restore
4.1 What is the Backup Controller Function?
The controller configuration set by EPSON RC+ 7.0 can be stored with the “Backup
Controller” function.
The Controller settings can be restored easily using the data previously stored with
Backup Controllerafter a configuration mistake or Controller problem.
Be sure to execute Backup Controller before changing the Controller setup, before
maintenance, or after teaching.
For some problems, backup may not be available before maintenance has to be performed.
Be sure to backup the data after making changes, before problems occur.
Controller status storage functionis one of the RC700 / RC700-A functions. It saves
the Controller setup data same as “Backup Controller.
There data can be used as the backup data at restoring.
The methods for Controller Status Storage” are as follows:
A : Controller backup to the USB memory
For details, refer to Setup & Operation 6. Memory Port.
B : Export Controller backup function” in EPSON RC+ 7.0.
For details, refer to EPSON RC+ 7.0 Users Guide 5.9.9 Import Command (Project
Menu).
4.2 Backup Data Types
The table below shows the files created with Backup Controller”.
File Name
Overview
Backup.txt
Information file for
restore
File including information for restoring
the Controller.
CurrentMnp01.PRM
Robot parameters
Stores information such as TlSet.
InitFileSrc.txt
Initial configuration
Stores various Controller parameters.
MCSys01.MCD
Robot configuration
Stores connected Robot information.
All the files related
to Project
Project related All the project files transferred to the
Controller. Includes program files when
EPSON RC+ 7.0 is configured to transfer
source code to the Controller.
GlobalPreserves.dat Global Preserve
variables
Saves values of Global Preserve
variables.
WorkQueues.dat WorkQue
information
Saves information of Queues information
of the WorkQue.
NOTE

Table of Contents

Other manuals for Epson RC700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC700 Series and is the answer not in the manual?

Epson RC700 Series Specifications

General IconGeneral
ModelRC700 series
CategoryController
Programming LanguageSPEL+
Safety StandardISO 10218-1
TypeRobot Controller
Communication InterfaceEthernet, RS-232, USB
Operating Temperature0°C to 45°C (32°F to 113°F)
Humidity20% to 80% (non-condensing)
Number of controllable robots4

Related product manuals