Maintenance 4. Backup and Restore
RC700 / RC700-A Rev.23 129
4.4 Restore
Restore the Controller status from the EPSON RC+ 7.0.
CAUTION
Make sure that the data used for restore was saved previously for same
Controller.
Do not edit the backup files. Otherwise, operation of the robot system
after data
restoration to the Controller is not assured.
(1) Select the EPSON RC+ 7.0 menu-[Tools]-[Controller] to display the [Controller
Tools] dialog.
(2) Click the <Restore Controller…> button to display the [Browse For Folder] dialog.
(3) Specify the folder that contains the backup data. Backup data folders are named
using the following format:
B_ RC700_ serial number_ date status was saved
→ Example: B_RC700_12345_2011-04-03_092941
Data saved to the USB memory by the Backup Controller function can also be
specified for restore.