Maintenance 5. Firmware Update
RC700 / RC700-A Rev.23 135
5.3 Controller Recovery
If the Controller becomes inoperable, use the procedures described in this section to
recover.
Controller Backup is recommended for easy recovery of the Controller operation. For
details of Controller Backup, refer to Maintenance 4. Backup and Restore.
The following two conditions describe the Controller error status after turning on
the Controller.
Condition A
The Controller automatically changes to Recovery mode and the LED of
ERROR, TEACH, and PROGRAM are lighting. You are a
ble to
communicate with the development PC though the
Controller does not
operate properly.
Condition B
The LED of TEACH, AUTO, and PROGRAM do not blink.
Cannot communicate with the Controller using the development PC.
Countermeasure for the error status is as follows.
Condition A
Follow Maintenance 5.4
Firmware Initialization Procedure to initialize the
firmware.
Condition B
Execute the following steps:
(1) Turn OFF the Controller.
(2) Push the trigger button located on the front side of the Controller and
while holding the button in, turn ON the Controller. Continue to
hold in the trigger button for 30 seconds.
This will cause the
Controller to start in Recovery mode.
(3) Make sure that the LED of ERROR, TEACH, and PROGRAM are
lighting.
(4) Follow the procedure in Maintenance
5.4 Firmware Initialization
Procedure from step (3) to initialize the firmware.
NOTE

Table of Contents

Other manuals for Epson RC700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC700 Series and is the answer not in the manual?

Epson RC700 Series Specifications

General IconGeneral
ModelRC700 series
CategoryController
Programming LanguageSPEL+
Safety StandardISO 10218-1
TypeRobot Controller
Communication InterfaceEthernet, RS-232, USB
Operating Temperature0°C to 45°C (32°F to 113°F)
Humidity20% to 80% (non-condensing)
Number of controllable robots4

Related product manuals