Maintenance 7. Maintenance Parts Replacement Procedures
166 RC700 / RC700-A Rev.23
DPB
Installation
(1)
Insert the
DPB to the chassis.
(2)
Fix the DPB with screws.
(3)
RC700
-A only: Mount the rear plate. (Mounting screw ×5)
(4)
RC700
-A only: Connect the regenerative fan extension connector.
(5)
Connect the eight connectors to the DPB.
(6)
Mount the MDB clamp 3. (Mounting screw
×2)
(7)
Mount the DMB.
Refer to: Maintenance
7.6 DMB
(8)
Mount the top plate. (Mounting screw
×6)
(9)
After connecting the power plug, turn on the Controller and check it works normally
without
vibration and abnormal sound.