Setup & Operation 12. I/O Remote Settings
RC700 / RC700-A Rev.23 71
(*10) The values specified by “SelAlarm1, 2, 4, and 8” correspond to the alarm numbers.
2
Battery of the robot connected to CU
0 1 0 0
3
Grease of the robot connected to CU
1 1 0 0
Battery of the robot connected to DU1
Grease of the robot connected to DU1
Battery of the robot connected to DU2
Grease of the robot connected to DU2
Battery of the robot connected to DU3
Grease of the robot connected to DU3
0=OFF, 1=ON
The following parts are subject to grease up.
6-axis robot: Bevel gear on the Joint #6
SCARA, RS series: Ball screw spline unit on the Joint # 3
(*11) The specified alarm can be canceled by selecting the conditions using SelAlarm1-SelAlarm8 and setting
this signal.
(*12) Operation of all tasks and commands, power mode of the robot, and PowerHigh command by the setting
of the controller preferences.
Preferences (1): “Motor power low when ForcePowerLow signal OFF”
Preferences (2): “ForcePowerLow signal change pauses all tasks”
For details of the controller preferences, refer to EPSON RC+ 7.0 User’s Guide
[Setup]-[System Configuration]-[Controller]-[Preferences] in 5.12.2 [System Configuration] Command
(Setup Menu).
Preferences (1) Preferences (2) ForcePowerLow
Power mode PowerHigh
0 0 0→1 Stop Low only
0 1 1→0 Continue High/Low