22 IR REMOTE CONTROLLER (REMC)
22-10
Seiko Epson Corporation
S1C17624/604/622/602/621 TECHNICAL MANUAL
D1 REMRIE: Rising Edge Interrupt Enable Bit
Enables or disables input signal rising edge interrupts.
1 (R/W): Interrupt enabled
0 (R/W): Interrupt disabled (default)
D0 REMUIE: Underflow Interrupt Enable Bit
Enables or disables data length counter underflow interrupts.
1 (R/W): Interrupt enabled
0 (R/W): Interrupt disabled (default)