Epson Stylus Pro GS6000 Revision F
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 131
Confidential
4.4.7.7 SUB TANK SENSOR
1. Remove the TOP COVER. (p85)
2. Remove the PANEL COVER, T. (p86)
3. Remove the SIDE COVER. (p89)
4. Remove the IH COVER. (p90)
5. Remove the eight screws and remove the fixing plate.
A) Silver, Phillips, Pan with S.W & P.W M3x6: four pieces
B) Silver, Phillips, Cup M3x6: four pieces
Figure 4-96. Removing the fixing plate
6. Remove the screw and push the SUB TANK ASSY inside to release it.
A) Silver, Phillips, Cup M3x6: one piece
7. Disengage the hooks and release the SUB TANK SENSOR (two each; top and
bottom).
8. Disconnect the connector and remove the sensor.
Figure 4-97. Removing the SUB TANK SENSOR
This sensor is used as a pair (top and bottom) on more than one
location, but basically you can remove other sensors in the
same way. Therefore this section describes the way to remove
the left most pair of sensors only. If you remove other than
those, remove the SUB TANK ASSYs from the left one by one
to the assy with your target sensors.
When removing the covers on the left, remove the MAINTE
COVER T (p88) in Step 2.
When removing the IH COVER on the left, remove six screws
only. See Figure 4-25.
After installation, make sure to apply thread locker around the
hooks to secure the sensors.