EasyManua.ls Logo

Epson Stylus Pro GS6000 - Page 130

Epson Stylus Pro GS6000
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Epson Stylus Pro GS6000 Revision F
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 130
Confidential
4.4.7.6 PG HEIGHT SENSOR
1. Remove the TOP COVER (left only). (p85)
2. Remove the MAINTE COVER T. (p86)
3. Remove the SIDE COVER (left only). (p89)
4. Unlock the Carriage. (p83)
5. Remove the CR Top Cover (Step 6 to 9 in 4.4.5.3 COOLING FAN). (p104)
6. Open the Top Frame (Step 6 to 9, and 11 in 4.4.7.5 CR ENC ASSY). (p128)
7. Remove the four screws from the Middle Frame.
A) Silver, Phillips, Pan with S.W & P.W M3x8: four pieces
8. Slide open the frame in the direction of the arrow.
Figure 4-94. Opening the Middle Frame
9. Disconnect the connector and disengage the hooks, then remove the PG HEIGHT
SENSOR.
Figure 4-95. Removing the PG HEIGHT SENSOR
A
As seen from the top
Middle Frame
After installation, make sure to apply thread locker around the
hooks to secure the sensors. See Figure 4-95.
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5 “Adjustment” (see p184) and perform
specified adjustments after replacing or removing this part.
<Adjustment item>
1. Sensor Test
Connector
PG HEIGHT SENSOR
Connector
As seen from the top
Middle Frame
Hook

Table of Contents