DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 129
Confidential
11. Move the Carriage to the platen and remove the two screws securing the CR ENC
ASSY from the hole on the rear left.
A) Silver, Phillips, Cup M2x4: two pieces
Figure 4-92. Removing the CR ENC ASSY (1)
12. Move the Carriage to the left end and open the Top Frame with SUB_A BOARD
to the left. See Figure 4-91.
13. Release the cable from the two clamps and remove the CR ENC ASSY from the
Middle Frame.
Figure 4-93. Removing the CR ENC ASSY (2)
Make sure you set back the green cable with the B screw when
reassembling.
A
As seen from the rear
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5 “Adjustment” (see p184) and perform
specified adjustments after replacing or removing this part.
<Adjustment item>
1. Encoder Test