LEVER SENSOR
Figure 4-104. Removing the LEVER SENSOR
The LEVER SENSOR is secured with hooks. To remove this
sensor, disengage the hooks and disconnect the cable.
When routing the cable of each sensor, make sure to give it one
turn around the clamps the same as the original routing.
After installation, make sure to apply thread locker around the
hooks to secure the LEVER SENSOR.
Be sure to refer to Chapter 5 “Adjustment” (see p184) and perform
specified adjustments after replacing or removing this part.
<Adjustment item>
1. Sensor Test