Epson Stylus Pro GS6000 Revision F
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 145
Confidential
4.4.9.3 CR ENC SCALE
1. Remove the TOP COVER (L & R). (p85)
2. Remove the PANEL COVER, T (p86) and MAINTE COVER T. (p88)
3. Remove the SIDE COVER (L & R). (p89)
4. Remove the REAR COVER.(p95)
5. Unlock the Carriage and move it to the center. (p83)
6. Remove the right end of the spring from the CR ENC SCALE on the left side.
Figure 4-111. Removing the spring
7. Remove each screw in the middle and remove the fixing plates one by one from
the left to the right (three plates in total).
A) Silver, Phillips, Cup M3x6: three pieces
Figure 4-112. Removing the fixing plates
Pay attention to the following instructions:
• Do not touch the CR ENC SCALE with bare hands or with
gloves stained with ink.
• Do not damage the CR ENC SCALE.
• Handle the Extension Spring in a way that does not extend
it.