Epson Stylus Pro GS6000 Revision F
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 176
Confidential
To make the operation easier when removing/installing the CR
CURSOR ASSY, it is recommended to put the upper part of the CR
CURSOR ASSY on the IH COVER as shown below.
Check if the CR CURSOR ASSY moves smoothly after
reassembling the assy.
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5 “Adjustment” (see p184) and perform
specified adjustments after replacing or removing this part.
<Adjustment items>
1. CR Height Adjustment
2. Nozzle Check Pattern
3. Cleaning and Washing
4. Head Slant and Alignment Adjustment
5. Head Nozzle Alignment Adjustment
6. Head Uni-D/Bi-D Low Gap Adjustment
7. Media Side Margin Adjustment
8. Sensor Test