DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 178
Confidential
TAKE-UP SENSOR
1. Remove the Take-Up Unit Cover (p177)
2. Disconnect the connectors of the TAKE-UP SENSORs.
3. Disengage the hooks behind, and remove the TAKE-UP SENSORs.
Figure 4-159. Removing the TAKE-UP SENSORs
TAKE-UP CONT BOARD ASSY
1. Remove the Take-Up Unit Cover (p177)
2. Remove the TAKE-UP SENSOR.(p178)
3. Remove the four screws on both sides at the bottom, and remove the Take-UP
Reel Unit (not an ASP).
A) Silver, Hexagon socket M4x10: four pieces
Figure 4-160. Removing the Take-Up Reel Unit
After installing the sensors, make sure to apply thread-locker to the
hooks behind.
Behind frame
Hooks
TAKE-UP SENSOR
Inside the box
Thread-lock area
Behind frame
TAKE-UP SENSOR
The other side
A
As seen from the front left
Take-UP Reel Unit