DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 183
Confidential
When installing the TAKE-UP MOTOR ASSY, screw the assy
while tilting it to apply tension to the chain using the motor's weight
as follows:
1. Attach the three screws marked below once without tightening
them to the full.
2. Tilt the Take-Up Reel Unit clockwise to apply tension to the
chain by the weight of the motor naturally as shown in the
figure below.
3. Tighten the three screws to the full with tension applied to the
chain.
4. Attach the Fixing plate. See Figure 4-167.
Chain
As seen from the right
TAKE-UP MOTOR ASSY
[Step 3]
Screw while
applying tension
to the chain.
[Step 2]
Tilt it to apply
weight of motor
to the chain.