TAKE-UP MOTOR ASSY
1. Remove the Take-Up Unit Cover (p177)
2. Remove the TAKE-UP SENSOR.(p178)
3. Remove the TAKE-UP CONT BOARD ASSY.(p178)
4. Remove the two screws and remove the fixing plate.
A) Silver, Phillips, Pan with S.W & P.W M4x8: two pieces
Figure 4-167. Removing the Fixing plate
5. Remove the three screws and remove the Chain.
A) Silver, Phillips, Pan with S.W & P.W M4x8: three pieces
Figure 4-168. Removing the Chain
6. Draw the TAKE-UP MOTOR ASSY from the hole and remove it.
Figure 4-169. Removing the TAKE-UP MOTOR ASSY