DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 181
Confidential
TAKE-UP P/S BOARD ASSY
1. Remove the Take-Up Unit Cover (p177)
2. Disconnect the TAKE-UP SENSOR.(p178)
3. Remove the TAKE-UP CONT BOARD ASSY.(p178)
4. Release the cables from the two clamps.
5. Remove the four screws and remove the shield plate.
A) Silver, Phillips, Pan with S.W & P.W M3x6: four pieces
Figure 4-165. Removing the Shield Plate
6. Disconnect the two connectors.
7. Remove the four screws and remove the TAKE-UP P/S BOARD ASSY.
A) Stud bolt: four pieces
Figure 4-166. Removing the TAKE-UP P/S BOARD ASSY
Connector assignment:
When routing the cables, make sure to give it one turn around the
clamp the same as the original routing as shown below.
A
Clamps
Inside the box
Shield Plate
Connector No. Color Destination
CN1
White AC Inlet
CN2
White TAKE-UP CONT BOARD ASSY (JP3)
A
TAKE-UP P/S BOARD ASSY
Inside the box
CN1
CN2
AC Inlet