TROUBLE SHOOTING Remedies for Service Call Error 58
Confidential
1911
Insufficient temperature of the
PLATEN HEATER(64) on the
HEATER RELAY BOARD
ASSY
The required temperature of the PLATEN HEATER(64) cannot be
reached.
Check whether the AC cable for the heater is properly connected. If not,
connect the cable properly.
Check whether the THERMISTOR, PLATEN(s) is correctly installed.
Check whether the THERMISTOR, PLATEN(s) is properly connected.
Check whether the FUSE has blown. If so, replace the FUSE.
Replace the HEATER RELAY BOARD ASSY (p.114).
1912
Insufficient temperature of the
AFTER HEATER(64) on the
HEATER RELAY BOARD
ASSY
The required temperature of the AFTER HEATER(64) cannot be
reached.
Check whether the AC cable for the heater is properly connected. If not,
connect the cable properly.
Check whether the THERMISTOR, AFTER(s) is correctly installed.
Check whether the THERMISTOR, AFTER(s) is properly connected.
Check whether the FUSE has blown. If so, replace the FUSE.
Replace the HEATER RELAY BOARD ASSY (p.114).
1920
HEATER CONT BOARD ASSY-
SUB TANK SENSOR 1 failure
The High sensor for the sub tank 1 is ON (ink exists), but the Low senor
is OFF.
Check whether the SUB TANK SENSOR is properly connected.
Replace the SUB TANK SENSOR (p.131).
1921
HEATER CONT BOARD ASSY-
SUB TANK SENSOR 2 failure
The High sensor for the sub tank 2 is ON (ink exists), but the Low senor
is OFF.
Check whether the SUB TANK SENSOR is properly connected.
Replace the SUB TANK SENSOR (p.131).
1922
HEATER CONT BOARD ASSY-
SUB TANK SENSOR 3 failure
The High sensor for the sub tank 3 is ON (ink exists), but the Low senor
is OFF.
Check whether the SUB TANK SENSOR is properly connected.
Replace the SUB TANK SENSOR (p.131).
1923
HEATER CONT BOARD ASSY-
SUB TANK SENSOR 4 failure
The High sensor for the sub tank 4 is ON (ink exists), but the Low senor
is OFF.
Check whether the SUB TANK SENSOR is properly connected.
Replace the SUB TANK SENSOR (p.131).
1924
HEATER CONT BOARD ASSY-
SUB TANK SENSOR 5 failure
The High sensor for the sub tank 5 is ON (ink exists), but the Low senor
is OFF.
Check whether the SUB TANK SENSOR is properly connected.
Replace the SUB TANK SENSOR (p.131).
1925
HEATER CONT BOARD ASSY-
SUB TANK SENSOR 6 failure
The High sensor for the sub tank 6 is ON (ink exists), but the Low senor
is OFF.
Check whether the SUB TANK SENSOR is properly connected.
Replace the SUB TANK SENSOR (p.131).
1926
HEATER CONT BOARD ASSY-
SUB TANK SENSOR 7 failure
The High sensor for the sub tank 7 is ON (ink exists), but the Low senor
is OFF.
Check whether the SUB TANK SENSOR is properly connected.
Replace the SUB TANK SENSOR (p.131).
1927
HEATER CONT BOARD ASSY-
SUB TANK SENSOR 8 failure
The High sensor for the sub tank 8 is ON (ink exists), but the Low senor
is OFF.
Check whether the SUB TANK SENSOR is properly connected.
Replace the SUB TANK SENSOR (p.131).
1A23
RTC analysis error The value information on various absolute time stored on NVRAM is
abnormal.
Check if the lithium battery is installed properly.
Replace the MAIN BOARD ASSY (p.110).
1A26
RTC communication error The communication with the RTC circuit cannot be made. Replace the MAIN BOARD ASSY (p.110).
Error Code Error Name Description Remedy/Point to be checked