TROUBLE SHOOTING Remedies for Service Call Error 59
Confidential
Note *: serial cable: communication cable between the MAIN BOARD ASSY and the HEATER CONT BOARD ASSY.
1A37
Head thermistor error There is something wrong with the Head FFC connection. Check whether the Head FFC is properly connected. If not (slant
connection or the like), correct it.
The Head Thermistor detects a temperature out of the specification. Replace the PRINT HEAD(s) (p.158).
The Head Thermistor has a defect.
1A38
Transistor thermistor error The transistor is faulty. Replace the PRINT HEAD(s) (p.158).
The thermistor detects a temperature out of the specification.
1A39
Head error The active signal of head error has been detected. Replace the PRINT HEAD(s) (p.158).
1A40
MAIN BOARD ASSY IC2 error
1A41
Head rank ID input error The information of the Head rank ID is wrong. Configure the head rank ID again.
2000
NVRAM error NVRAM erase or write error has occurred. Replace the MAIN BOARD ASSY (p.110).
2002
SDRAM error SDRAM read/write error has occurred. Replace the MAIN BOARD ASSY (p.110).
2003
Boot program sum error Installation of the firmware has been failed. Install the main firmware again.
Replace the MAIN BOARD ASSY (p.110).
The Flash ROM is faulty. Replace the MAIN BOARD ASSY (p.110).
200A
Program loading error The SDRAM is faulty.
The program cannot be loaded on the SDRAM.
Replace the MAIN BOARD ASSY (p.110).
200B
Internal insufficient memory error The main firmware has a defect. Install the correct main firmware.
200C
Servo interrupt watchdog time-out
error
The servo cannot be controlled. Install the correct main firmware.
Replace the MAIN BOARD ASSY (p.110).
200D
System interrupt watchdog time-
out error
A system failure such as CPU failure, defective cash or the like has
occurred.
Replace the MAIN BOARD ASSY (p.110).
200E
Unknown NMI The CPU has detected an unknown NMI. Replace the MAIN BOARD ASSY (p.110).
3000
AC power shut-off The AC power has been shut off due to a power failure, unplugged, P/S
BOARD ASSY failure, or MAIN BOARD ASSY failure or the like.
Check whether the AC cable is properly connected. If not, correct it.
Replace the P/S BOARD ASSY (p.117).
Replace the MAIN BOARD ASSY (p.110).
DXXX Debug error The firmware has a defect.
Restart the printer.
Reinstall the firmware.
The MAIN BOARD ASSY is broken.
Replace the MAIN BOARD ASSY (p.110)
FXXX
CPU-related error The firmware has a defect. Install the correct main firmware.
The MAIN BOARD ASSY is broken. Replace the MAIN BOARD ASSY (p.110).
Error Code Error Name Description Remedy/Point to be checked