7800/7700 MultiFrame Manual
7814 Series Dual HDTV Up/Down/Cross Converters
Revision 1.1.3 Page - 31
6.2.4.5. Auto Reference Valid Timeout
The Reference Valid Timeout sets a user specified time that the reference input will return to the Priority 1
Reference when a valid genlock signal is re-asserted.
6.2.4.6. Auto Reference Invalid Timeout
This control allows the user to set a timeout length when a reference signal is lost on the Priority 1
Reference input. Once the module confirms that, the genlock input is no longer valid
6.2.4.7. Auto Reference Status Monitor
The Auto reference Status Monitor is used to see what the current Priority the module is under. It will
report either Priority 1 or Priority 2 and the source of the current genlock input.
6.2.4.8. Auto Reference Reset Button
The Reference Reset Button allows the user to reset the Prioritized Reference Fail Over back to original
settings
6.2.4.9. Reference Changed Event
The Reference Changed Event trap will send a monitoring trap back to VLPro in the event the module
losses input reference and changes over to the next priority reference input. To enable a specific Fault
trap, click the small box beside the relevant fault and ensure that a check mark appears in the box. To
disable a specific Fault trap, click the small box beside the relevant fault and ensure that a check mark
does not appear in the box.