SMP 300 Series • Remote Communication and Control 110
Symbol definitions
]
=
CR/LF (carriage return/line feed)
}
or |
=
Carriage return
or pipe symbol (no line feed, hex = 0D)
• =
Space
E
or W
=
Escape
X!
=
Inputs 1 to 4 (1 to 5 for SDI models)
X*
=
Status
0 = Offline
1 = Live
X(
=
0 = Disabled/unassigned/off/unmuted (default)
1 = Enabled/assigned/on/muted
X1)
=
Configuration type
0 = IP Config (ip.cfg)
2 = Box specific parameters (box.cfg)
X1!
=
Firmware version number
X1@
=
Device name (63 characters, max)
Must comply with internet host name standards.
X1#
=
Day, date, and time (Day,•MM•DD•YY‑HH:MM:SS)
X1$
=
Time zone acronym (2 to 6 letters)
X1%
=
Greenwich Mean Time (GMT) offset value: -12:00
to 14:00. Represents hours and minutes (HH:MM)
offset from GMT including the time zone name.
X1^
=
IP address in dotted decimal notation
(xxx.xxx.xxx.xxx)
Default: 192.168.254.254 (no padding)
Default gateway IP address: 0.0.0.0
Default DNS server IP address: 0.0.0.0
X1&
=
Subnet mask
Default: 255.255.0.0 (no padding)
X1*
=
Hardware MAC address
(00-05-A6-NN-NN-NN)
X1( Time in tens of milliseconds to wait for characters
coming into a serial port before terminating (min =
0, max = 32767 and, default = 10 = 100 ms). The
response is returned with leading zeros.
X2) Time in tens of milliseconds to wait between
characters coming into a serial port before
terminating (min = 0, max = 32767, and default =
2 = 20 ms). The response is returned with leading
zeros. Commands using both
X1&
and
X2)
must
have both values = 0 or both set to non‑zero.
X2!
=
Parameter to set either Length of message to
receive or Delimiter value. L=#=byte count (min = 0,
max = 32767, default = 0L = 0 byte count).
D = Decimal value for ASCII character (min = 0, max
= 00255, default = 00000L). Value is placed prior to
parameter: 3 byte length = 3L and ASCII 0A delimiter
is 10D.
The parameter is case sensitive, and must use
capital D or capital L. The response is returned with
leading zeros.
X2@
=
Priority status for receiving timeouts —
0 = Use Send data string command parameters (if
they exist) (default).
1 = Use Configure receive timeout command
parameters instead.
X2#
=
Verbose mode
0 = Clear/none (default for Telnet connections)
1 = Verbose mode (default for USB and RS‑232 host
control)
2 = Tagged responses for queries
3 = Verbose mode and tagged responses for queries
X2$
=
Temperature — Degrees in Celsius (example: xx.xC)
X2%
=
RS‑232 baud rate (9600 [default], 19200, 38400,
57600, 115200)
X2^
=
RS‑232 parity — single letter:
Odd, Even, None (default), Mark, Space
X2&
=
RS‑232 data bits — 7, 8 (default)
X2*
=
RS‑232 stop bits — 1 (default), 2
X2(
=
Input mode
0 = Off
1 = ES RTP Push
2 = RTSP Pull
X3)
=
Audio format
0 = Disable audio
1 = Analog (default of input 3)
2 = LPCM 2 CH (default)
X3!
=
Authentication type
0 = Off
1 = Basic
2 = Digest
X3@
=
Connection status
0 = NA
1 = Disconnected
2 = Connected
X3#
=
Password — Maximum length 128 characters. All
alpha‑numeric characters permitted except |, and
"space".
NOTE: The factory configured passwords
for all accounts on this device have been
set to the device serial number. In the
event of a complete system reset, the
passwords convert to the default, which
is no password.
X4)
=
Encode profile
1 = Base
2 = Main
3 = High
X4!
=
Output mode
1 = Video and audio
2 = Video only
X4@
=
Bit rate control type
0 = VBR (default)
1 = CVBR
2 = CBR
X4#
=
Video bit rate — 200 to 10000