9 Measurement
9.1 Parameter input FLUXUS F60*
2017-10-16, UMFLUXUSF60xV5-0EN
84
Pipe material
The pipe material has to be selected to be able to determine the corresponding sound
speed.
The sound speeds for the materials in the scroll list are stored in the transmitter.
Select the pipe material.
Press ENTER.
If the material is not in the scroll list, select Other Material.
Press ENTER.
Sound speed of the pipe material
Enter the sound speed of the pipe material.
Press ENTER.
These displays will only be indicated if Other Material is selected.
For the sound speed of some materials, see annex C.
Lining
Select yes if the pipe has a lining. Select no if the pipe has no lining.
Press ENTER.
Lining material
Select the lining material.
Press ENTER.
If the lining material is not included in the scroll list, select Other Material.
Press ENTER.
This display will only be indicated if yes is selected in the menu item Lining.
Parameter\Pipe Material
Parameter\Pipe Material\Other Material\c-Material
Notice!
There are 2 sound speeds for pipe materials, the longitudinal and the transversal
one. Enter the sound speed which is nearer to 2500 m/s.
Parameter\Lining
Parameter\Lining

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flexim FLUXUS F60 Series and is the answer not in the manual?

Flexim FLUXUS F60 Series Specifications

General IconGeneral
BrandFlexim
ModelFLUXUS F60 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals