185
PRIMERGY RX300 S3 User's Guide
7
Installing Internal Options
7.3.2 Installable CPUs and Notes
■ Installable CPUs
The following types of CPUs can be installed on this server. When installing an optional CPU, the two 
CPUs must have the same product name (same frequency/cache size).
 Before installing an optional CPU, see "B.1 CPU" (pg.292) to check the packaged product.
7.3.3 How to Install the CPU
1 Turn off the power and remove the top cover.
"7.2 Installing/Removing the Top Cover" (pg.182)
2 Touch a metal part of the server to discharge static electricity.
3 Remove the fan duct.
Lift and remove the fan duct.
table: List of Installable CPUs
Product name Model
Processor Xeon 5050 3GHz / 2 x 2MB PG-FG32M
Processor Xeon 5060 3.20GHz / 2 x 2MB PG-FG32N
Processor Xeon 5080 3.73GHz / 2 x 2MB PG-FG32P
Fan duct