63
PRIMERGY RX300 S3 User’s Guide
3
OS Installation Using ServerStart
Configuring RAID
1 Select [Mass Storage Controller View] on the [Configuration for Disks and RAID
Controllers] window.
Click [Details]. As the default values are configured, confirm the settings and modify them as
necessary.
Add partitions as necessary.
Configure the setting as follows to configure RAID with the PG-142E3 card.
For guided mode
Select [MegaRAID SAS PCI Express
TM
ROMB] for [RAID Controller].
For preconfiguration mode
Select [1] for [Controller number] in details settings.
One hot spare (standby disk) can be configured. When the hot spare disk is set to "Yes", set
the number of disk units to the number of installed disk units minus 1.
E.g.: When four hard disk units are installed, set the RAID level to "RAID5", and when the hot
spare disk is set to "Yes", set the number of disk units to "3".