IIDTool
GAP Diagnostic 2019-07-15 All Rights Reserved
User Manual : Version 33, Firmware V3.0
4.6 Function “ Calibration ” of systems and components
4.6.1 Denition
A calibration is used to corroborate a physical quantity associated with a signal or value provided by a
sensor.
Access
1- Perform the initial stages of access (section 4.1.3)
2- Select “ Calibration ”
3- Navigate through the ECU using commands
4- Select the desired ECU
5- Select the required calibration
4.6.2 Steering Angle Sensor (L322, L319, L320, L316*)
Steering angle sensor calibration
This routine will calibrate the steering angle sensor centre position.
*SeeengineforL3162012.
Preparations
•Placethevehicleonaatandlevelsurface.
•Ensurethatyourfrontwheelsandsteeringwheelarestraightbeforeproceeding.
Usages
This function is used when:
•Thesteeringanglesensorisreplaced.
•Awheelalignmentisperformedonthevehicle.
•Itmayberequiredifpartsofthesteeringsystemhavebeenreplacedorremoved.
Steering angle sensor renew (L322-02, L322-06)
This routine is used when the steering angle sensor is replaced.
4.6.3 Parking Brake (L322-06, L322-10, L319, L320)
Longitudinal Accelerometer Sensor Calibration
This routine is used when the EPB ECU is replaced.
Preparations
•Placethevehicleonaatandlevelsurface.
•Thevehicleshouldstaystationaryforthedurationoftheroutine.
•TheEPBECUmustbefastenedsecurelyandtheparkingbrakemustbeapplied.
•Makesurethebrakepedalisreleased.